Dantherm Attic & Wall Mounted MVHR Unit / RCV 320 Mechanical Ventilation & Heat Recovery System. Attic and wall-mounted home ventilation units. The RCV 320 is a highly efficient and very compact residential ventilation unit for houses, villas, and apartments. Based on patent-pending technology and an ingenious design, it is delivered as a true plug and play solution with a built-in control panel and all necessary parts for on-site wall installation.

All units come with an Aluzinc surface finish and will be packaged four units on a pallet at a time to ease handling at building sites. In addition to speeding up your installation work, this reduces the amount of packaging materials for you to get rid of while also benefitting the environment.

Share:

Key features

Key features of the Dantherm RCV 320 Attic & Wall Mounted Unit.

  • Demand-controlled ventilation with integrated humidity sensor, reducing power consumption at times with low ventilation demands.
  • Summer mode in which the supply fan is stopped and any open window will supply cooler outside air, lowering the room temperature.
  • Automatic free-cooling features, including the possibility of increasing the air flow automatically, lets in cool night air following hot days to help maintain a comfortable temperature throughout the day.
  • Fireplace mode, creating a temporary inside overpressure to enhance chimney functionality.
  • High-efficiency heat recovery.
  • EC fan motors with extremely low energy consumption (low SPI).
  • Highly customisable units with the option to add a high variety of internal as well as external accessories.
  • Ducts can be connected through the top of the unit, either side or the bottom as preferred.
  • Compact design.
  • Internal pre-heater as accessory.
Technical data

Technical data and specifications for the Dantherm RCV 320 Attic & Wall Mounted Unit.

SPECIFICATIONS
UNITS
RCV 320
Maximum flow at 100Pam3/h320
Max. rated flow at 100PaVmax.rated + m³/h200
Operating range DIBtVDIBt | m³/h70 – 200
Operating range Passivhaus at 100PaVPHI | m³/h70 – 160
EN 13141-7 reference flow at 50PaVREF | m³/h140
Performance%<2% (Class A1)
Thermal efficiency in accordance with PHIηSUP | %92
Thermal efficiency in accordance with EN13141-7ηSUP | %90
Leakage (external and internal) in accordance with EN 13141-7<2% (Class A1)
Filters in accordance with ISO16890ISO Coarse 75% (optional on supply: ePM1>50% )
Filters in accordance with EN779G4 (optional on supply: F7)
Installation surrounding temperaturetSURR | °C-12 to +50
Outdoor temperature without preheater installedtODA | °C-12* to +50
Outdoor temperature with preheater installedtODA | °C-20 to +50
Maximum absolute humidity of extract airx | g/kg10
CABINET
Dimensions (without bracket)mm | w x d x h600 x 603 x 526**
Spigots/ducts connectionsØmm8 pcs ø125 and 2 pcs oval (68 x 163) – female
Weightkg35
Thermal conductivity – polystyrene insulationλ | W/mK0.031
Heat transition figures – polystyrene insulationU | W/m²KU<1
Fire classification of the polystyrene insulationclassDIN 4102-1 class B2
Drainage hose includedØ/length | “/mø¾” – 1m
Cabinet colourRALno paint/raw Alu-zinc
ELECTRICAL
VoltageU | V230
Maximum power consumption (without/with preheater)P | W170/1070
Frequencyf | Hz50
Protection classIP21